Chapter 3 Operation

171

[3] Electric Gear Settings for Feedback Pulse

This is the parameter to determine the output pulse corresponding to the actuator

movement amount. Determine the movement amount per pulse to define how many

millimeters you would like the actuator to move with the output of 1 pulse.

Movement in line axis per pulse = Minimum output unit (1, 0.1, 0.01mm etc.)/pulse

Movement in rotary axis per pulse = Minimum output unit (1, 0.1, 0.01deg etc.)/pulse

(1) Selecting used feedback pulse gear ratio (Parameter No.114)

No.

Name

Symbol

Unit

Input

Range

Initial

Value

114

Selecting used feedback pulse gear ratio

FPIO

0 to 1

0

0: It outputs the pulse equivalent to the input pulse.

If the movement amount of input pulse is 0.01mm, 1 pulse is output when moved for

0.01mm. Thus, 1 pulse is output in response to 1 pulse of input.

Output pulse is determined by the electric gear for input (Parameters No.65 and 66).

1: The relation of the output pulse and the actuator movement can be set freely. Set the

electric gear in Parameters No.115 and 116.

(2) Electrical Gear (Feedback Pulse) (Parameter No.115, No.116)

Set these parameters when the relation of the output pulse and the actuator movement are to

be set freely.

These parameters are enabled when Parameter No.114 is set to 1.

User Parameter No.115/116 Electronic Gear (Feedback Pulse) Numerator/Denominator

Name

Symbol

Unit

Input Range

Initial Value

(For reference)

Electronic Gear

Numerator

FNUM

1 to 4096

125

Electronic Gear

Denominator

FDEN

1 to 4096

2048

Electronic Gear Formula:

In the case of Line Axis

In the case of Rotary Axis

Note 1 : Refer to 10.4 List of Specifications of Connectable Actuator for the encoder pulse of

each actuator.

Formula for velocity:

The velocity of the actuator is in proportion to the frequency of the output pulse.

Velocity = Movement amount per pulse � Output Pulse Frequency [Hz]

Electronic Gear

Numerator (FNUM)

Electronic Gear

Denominator (FDEN)

= Ball Screw Lead Length [mm/rev]

No. of Encoder Pulses [pulse/rev]

Movement amount per pulse [mm]

= 360 [deg/rev] � Rotary Axis Reduction Ratio

No. of Encoder Pules [pulse/rev]

� Movement amount per pulse [mm]

Electronic Gear

Numerator (FNUM)

Electronic Gear

Denominator (FDEN)

1

1