Chapter 3 Operation

170

[2]� Format Settings for Feedback Pulse

Set the format of output pulse in Parameter No.69 and active high/low in No.70.

(1) Feedback Pulse Train

No.

Name

Symbol

Unit

Input

Range

Initial

Value

69

Feedback Pulse Train

FBPT

0 to 2

0

(2) Feedback Pulse Form Polarity

No.

Name

Symbol

Unit

Input

Range

Initial

Value

70

Feedback Pulse Form Polarity

FBPT

0 to 1

0

0: Disable

1: Enable

AFB•/AFB

BFB•/BFB

AFB•/AFB

BFB•/BFB

AFB•/AFB

BFB•/BFB

AFB•/AFB

BFB•/BFB

AFB•/AFB

BFB•/BFB

AFB•/AFB

BFB•/BFB

ZFB•/ZFB

High

Low

High

Low

2

1

0

2

1

0

Normal Rotation

Pulse String

Normal Rotation

Pulse String

Reverse Rotation

Pulse String

Reverse Rotation

Pulse String

The normal rotation pulse string shows the motor rotation amount in normal direction, and reverse

rotation pulse string shows the motor rotation amount in reverse direction.

Pulse Train

Pulse Train

Symbol

Symbol

The command pulse shows the motor rotation amount and the command symbol shows the

rotation direction.

A/B Phase

Pulse String

A/B Phase

Pulse String

The A/B Phase 4-fold Pulse with the phase difference of 90° shows the commands for

the rotation amount and direction.

Command Pulse

String Mode

Input

Terminal

In Normal Rotation

In Reverse Rotation

Setting Value

of Parameter

No. 69

Negative Logic

Positive Logic

When the actuator encoder is other than the serial encoder, the Z-phase
signal is output as it is. In the case of serial encoder, the range of ±0.5°
of mechanical angle from the point 0 position (origin), is output as
the Z-phase signal.
Only when the motor rpm is 100rpm or less, this accuracy can be
guaranteed for the communication frequency with the encoder.
* When the encoder pulse count is 16384 (Pulse/rev), it shows the serial
encoder.