IAI America SCON-CA User Manual

Page 134

Advertising
background image

Chapter 3 Operation

124

Control method

1) When start signal ST* is turned ON, the actuator starts acceleration based on the data in

the specified position table for positioning to the target position.

2) At the completion of positioning, positioning complete signal PEND is turned ON as well as

current position No. PE* of the specified position.

3) After PEND is turned ON, turn the ST* signal OFF.

4) Current position No. PE* and positioning completion signal PEND are turned ON if the

remaining moving distance is entered into the positioning width zone. PE* and PEND

turned ON once remain ON unless start signal ST* is turned ON again or the servo is

turned OFF. They are also turned OFF when pause signal *STP is turned OFF.

Caution: (1) If the ST* signal is turned ON for the position after completion of

positioning, both the PE* and PEND signals remain ON (except the

pitch feed operation).

(2) Both the PE* and PEND signals are set to ON in the positioning

width zone. Accordingly, they may be turned ON under operation of

the actuator if a large positioning width is set.

(3) Interlock should be taken so that two or more ST* signals are set to

ON simultaneously�

1) Entering the ST* signal of another position during positioning is

invalid. If the ST* signal of another position is turned ON during

positioning, the operation is terminated after the completion of

the positioning being operated.

2) Entering the ST* signal of another position with the ST* signal of

the current position remaining ON after the completion of

positioning allows the positioning to the other position to be

executed.

(4) If Parameter No.27 “Move command type” is set to “0” (factory

setting), turning ST* OFF during positioning caused the operation to

be interrupted.

Start signal

ST*

(PLC�Controller)

Positioning Completion Signal

PEND

(Controller�PLC)

Turned ON after

entering into

positioning width zone

Current Position No.

PE*

(Controller�PLC)

Turned OFF by turning PEND ON

Advertising