Digital inputs, Warning – Proface LT4300M - 5.7 Modular HMI + Control" User Manual

Page 132

Advertising
background image

132

Digital Inputs

Digital Input Characteristics

The table describes the characteristics of the digital inputs:

High-speed Counter Digital Input Characteristics

WARNING

UNINTENDED EQUIPMENT OPERATION
Do not exceed any of the rated values specified.
Failure to follow these instructions can result in death, serious injury, or equipment
damage.

Characteristic

Value

Rated current

5 mA

Inrush values

Voltage

30 Vdc

Current

6.29 mA max.

Input impedance

4.9 k

Ω

Input type

Sink/Source

Rated voltage

24 Vdc

Maximum Allowable Voltage

28.8 Vdc

Input limit values

ON Voltage

15 Vdc or more (15...28.8 Vdc)

OFF Voltage

5 Vdc or less (0...5 Vdc)

ON Current

2.5 mA or more

OFF Current

1.0 mA or less

Isolation

Method

Photo coupler Isolation

Between internal
logic

500 Vdc

Filtering

0.5 ms x N (N is 0 to 63)

IEC61131-2 edition 3 type

Type 1

Compatibility

Supports 2 wire and 3 wire sensors

Cable type and length

Shielded: Maximum 100 m (328 ft)
Non-shielded: 50 m (164 ft)

Terminal blocks

Type: 3.5 mm (0.137 in.) pitch
Terminal blocks are removable

Input paralleling

No

WARNING

UNINTENDED EQUIPMENT OPERATION
Do not exceed any of the rated values specified.
Failure to follow these instructions can result in death, serious injury, or equipment
damage.

Advertising