Power supply characteristics and wiring, Danger, Warning – Proface LT4300M - 5.7 Modular HMI + Control" User Manual

Page 76

Advertising
background image

LT Installation

76

Power Supply Characteristics and Wiring

Overview

This section provides the wiring diagrams and the characteristics of the DC power supply.

Power Supply Voltage Range

If the specified voltage range is not maintained, outputs may not switch as expected. Use
appropriate safety interlocks and voltage monitoring circuits.

DC Power Supply Characteristics

DANGER

FIRE HAZARD
Use only the recommended wire sizes for I/O channels and power supplies.
Failure to follow these instructions will result in death or serious injury.

WARNING

UNINTENDED EQUIPMENT OPERATION
Do not exceed any of the rated values specified.
Failure to follow these instructions can result in death, serious injury, or equipment
damage.

Reference

Specification

Voltage

rated

24 Vdc

range

20.4...28.8 Vdc

Power interruption time

10 ms at 20.4 Vdc

Maximum inrush current

30 A at 25

° C and at 28.8 Vdc

Continuous
output power

with display

LT-4000M (Modular Type DIO) and
PFXXM4200TP (3.5 inch display
module) : 9 W

LT-4000M (Modular Type Analog)
and PFXXM4300TP (5.7 inch
display module): 13 W

without display LT-4000M (Modular Type DIO):

7 W

LT-4000M (Modular Type Analog):
10 W

Insulation Resistance

500 Vdc, 10 M

Ω or more

Isolation between DC power
supply and internal logic, I/O,
and protective ground (PE)

500 Vdc for 1 minute

Power supply reverse
protection

Yes

Advertising