LT System General Implementation Rules

30

Environmental Characteristics

Enclosure Requirements

LT system components are designed as Zone B, Class A industrial equipment according to
IEC/CISPR Publication 11. If they are used in environments other than those described in the
standard, or in environments that do not meet the specifications in this manual, the ability to meet
electromagnetic compatibility requirements in the presence of conducted and/or radiated
interference may be reduced.
All LT system components meet European Community (CE) requirements for open equipment as
defined by EN61131-2. You must install them in an enclosure designed for the specific
environmental conditions and to minimize the possibility of unintended contact with hazardous
voltages. Use a metal enclosure to improve the electromagnetic immunity of your LT system. Use
enclosures with a keyed locking mechanism to minimize accidents

Environmental Characteristics

LT meets CE requirements as indicated in the table below, and is intended for use in a Pollution
Degree 2 industrial environment.
The table below gives the general environmental characteristics:

Characteristic

Specification

Standard
compliance

IEC61131-2

Ambient operating
temperature for the
display and the
rear module

Horizontal installation

0...50

° C (32...122° F)

Vertical installation

0...40

° C (32...104° F)

Storage temperature

- 20...60

° C (- 4...140° F)

Storage altitude

0...10,000 m (0...32,808 ft)

Operating altitude

0...2,000 m (0...6,560 ft)

Surrounding Air and Storage Humidity

5...85% w/o condensation (non-condensing, wet
bulb temperature 39

° C (102.2° F) or less)

Degree of pollution IEC60664

2

Degree of
protection

IEC61131-2

IP20 with protective covers in place

Corrosive gases

Free of corrosive gases

Dust

≤ 0.1 mg/m

3

(10

-7

oz/ft

3

) (non-conductive levels)

Atmospheric pressure (Operating Altitude)

800...1,114 hPa (2000 m (6,561 ft) or lower)

Vibration
resistance

Mounted on a DIN rail

3.5 mm (0.138 in.) fixed amplitude from 5...8.4 Hz
9.8 m/s

2

(1 g

n

) fixed acceleration from 8.4...150 Hz

Mounted on a panel

3.5 mm (0.138 in.) fixed amplitude from 5...8.6 Hz
9.8 m/s

2

(1 g

n

) fixed acceleration from 8.6...150 Hz

Mechanical shock
resistance

Mounted on a DIN rail

147 m/s

2

(15 g

n

) for a duration of 11 ms

Mounted on a panel

147 m/s

2

(15 g

n

) for a duration of 6 ms