Actron CP9190 User Manual

Page 143

Advertising
background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 6 – 21

Ford Historic (OBD I) Diagnostics

6

4. Wiggle Test instructions.

•Use the

LEFT or RIGHT arrow key to view wiggle test

instructions or not.

•Press

ENTER to continue.

Instructions are available for
viewing. The default is Yes. If No is
selected, the test begins to
initialize.

If Yes is selected, the following instructions appear.

Gently tap and shake the sensor.

Wiggle the sensor connectors.

Twist and shake the wiring between the sensor and the PCM.

5. Start KOEO/KOER Wiggle Test.

•Press

ENTER.

After the 10-second initialization
period, the Scan Tool is ready for
the Wiggle Test. Locate the
suspect sensor or circuit
according to the above
instructions.

If a fault is detected, the Scan Tool
beeps and displays a FAULT
PRESENT message. A DTC(s) is
stored in the PCM and the Scan
Tool.

6. Return to On Demand Test

Menu.

•Press

BACK

.

View instructions

for wiggle test?

<Yes>

No

KOEO Wiggle Test

Wiggle Test Running.

Status:

*** Circuit OK ***

KOEO Wiggle Test

Wiggle Test Running.

Status:

*** Fault Present ***

KOEO Wiggle Test

Advertising