Actron CP9190 User Manual

Page 207

Advertising
background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • A – 27

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • PID Definitions

A

O2 1/1 STATE (V)

Oxygen Sensor Signal

O2 1/2 STATE

Oxygen Sensor State

O2 1/2 STATE (V)

Oxygen Sensor Signal

O2 1/3 STATE

Oxygen Sensor State

O2 1/3 STATE (V)

Oxygen Sensor Signal

O2 2/1 STATE

Oxygen Sensor State

O2 2/1 STATE (V)

Oxygen Sensor Signal

O2 2/2 STATE

Oxygen Sensor State

O2 2/2 STATE (V)

Oxygen Sensor Signal

O2 AVG BIAS

Oxygen Average Bias Voltage

O2 BNK1 #1

Oxygen Sensor Bank 1 Sensor 1

O2 HEATER TEST

Oxygen Heater Test

O2 HTR 1

Oxygen Heater Time To Activity Sensor 1

O2 HTR 1-1

Oxygen Heater Time To Activity Bank 1 Sensor 1

O2 HTR 1-2

Oxygen Heater Time To Activity Bank 1 Sensor 2

O2 HTR 1-3

Oxygen Heater Time To Activity Bank 1 Sensor 3

O2 HTR 2

Oxygen Heater Time To Activity Sensor 2

O2 HTR 2-1

Oxygen Heater Time To Activity Bank 2 Sensor 1

O2 HTR 2-2

Oxygen Heater Time To Activity Bank 2 Sensor 2

O2 HTR 2-3

Oxygen Heater Time To Activity Bank 2 Sensor 3

O2 HTR CUR

Oxygen Heater Current

O2 HTR DUTY CYC

Oxygen Heater Duty Cycle

O2 HTR DWNSTRM

Downstream Oxygen Heater

O2 HTR RELAY

Oxygen Heater Relay

O2 HTR UPSTRM

Upstream Oxygen Heater

O2 LN-RH 1-1

Oxygen Response Lean To Rich Switches Bank 1 Sensor 1

O2 LN-RH 1-2

Oxygen Response Lean To Rich Transition Time Bank 1 Sensor 2

O2 LN-RH 2-1

Oxygen Response Lean To Rich Transition Time Bank 2 Sensor 1

O2 LN-RH AV

Oxygen Lean/rich Average Time

O2 LN-RH TNS

Oxygen Lean/rich Transitions

O2 L-R SW 1-2

Oxygen Response Lean To Rich Switches Bank 1 Sensor 2

O2 L-R SW 2-1

Oxygen Response Lean To Rich Switches Bank 2 Sensor 1

O2 RH-LN 1-1

Oxygen Response Rich To Lean Transition Times Bank 1 Sensor 1

O2 RH-LN 1-2

Oxygen Response Rich To Lean Transition Time Bank 1 Sensor 2

O2 RH-LN 2-1

Oxygen Response Rich To Lean Transition Time Bank 2 Sensor 1

O2 RH-LN AV

Oxygen Rich/lean Average Time

O2 RH-LN TNS

Oxygen Rich/lean Transitions

O2 R-L SW1-1

Oxygen Response Rich To Lean Switches Bank 1 Sensor 1

O2 R-L SW2-1

Oxygen Response Rich To Lean Switches Bank 2 Sensor 1

O2 RSP R-L 1-1

Oxygen Response Rich To Lean Switches Bank 1 Sensor 1

O2 SEN 1

Oxygen Sensor 1 Volts

O2 SEN 1/1

Oxygen Sensor 1/1

O2 SEN 1/2

Oxygen Sensor 1/2

O2 SEN 1/3

Oxygen Sensor 1/3

O2 SEN 2

Oxygen Sensor 2 Volts

O2 SEN 2/1

Oxygen Sensor 2/1

O2 SEN 2/2

Oxygen Sensor 2/2

O2 SENSOR

Oxygen Sensor

O2 SEN STATE

Oxygen Sensor State

O2 SEN STATE (V)

Oxygen Sensor Signal

O2 SEN STATE1

Oxygen Sensor State

O2 SEN STATE1 (V)

Oxygen Sensor Signal

O2 SEN STATE2

Oxygen Sensor State

O2 SEN STATE2 (V)

Oxygen Sensor Signal

PID

Extended Description

Advertising
This manual is related to the following products: