Actron CP9190 User Manual

Page 92

Advertising
background image

Global OBD II Diagnostics

4 – 28 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

4 4

O2 sensors are located before (upstream) and after (downstream)
catalyst(s). Sensors are named (xy) for their position to both cylinder
banks and catalysts.

The O2 sensor for cylinder bank 1 has prefix 1y while O2 sensor
for cylinder bank 2 has prefix 2y.

The O2 sensor upstream of catalyst (closest to engine) has suffix
x1 while O2 sensor downstream of catalyst has suffix x2. If
vehicle contains more catalysts, O2 sensor downstream of
second catalyst has suffix x3 and O2 sensor downstream of next
catalyst has suffix x4.

For example, O2S21 is upstream O2 sensor for cylinder bank 2.

The following O2 Sensor Tests are available:

1) Rich-to-lean sensor threshold voltage

2) Lean-to-rich sensor threshold voltage

3) Low sensor voltage for switch time

4) High sensor voltage for switch time

5) Rich-to-lean sensor switch time

6) Lean-to-rich sensor switch time

7) Minimum sensor voltage test cycle

8) Maximum sensor voltage test cycle

9) Time between sensor transitions

10) Sensor period

11) Manufacturer specific tests

From the Special Tests Menu:
1. Select O2 Monitor Test.

•Use

UP or DOWN arrow

key until O2 Monitor Test is
highlighted.

•Press

ENTER.

I/M Readiness

?

Drive Cycle Monitor

State OBD Check

O2 Monitor Test

Diag Mon Tests

On-Board Systems

Vehicle Info

Special Tests Menu

O2 Monitor Test