Items measured at Power quality measurement

KEW6315

- 149 -

KEW6315

Items measured at Power quality measurement
Voltage transient

Meas. system

Approx. 40.96ksps (every 2.4µs) gapless event detection (50Hz/60Hz)

Displayed digit

4-digit

Effective
input range

50V - 2200V (DC)

Display range

50V - 2200V (DC)

Accuracy

0.5%rdg * at 1000V (DC)

Input impedance

Approx. 1.67MΩ

Threshold value

Absolute peak voltage value

Detection channel (ch)
1P2W-1 to 4

V

1

1P3W-1 to 2

V

1

, V

2

3P3W-1 to 2

Line voltage V

12 ,

V

32

3P3W3A

Line voltage V

12 ,

V

23 ,

V

31

3P4W

V

1 ,

V

2 ,

V

3

Voltage swell, Dip, INT

Range

Same as r.m.s. voltage

Displayed digit

Same as r.m.s. voltage

Effective
input range

Same as r.m.s. voltage

Display range

Same as r.m.s. voltage

Crest factor

Same as r.m.s. voltage

Input impedance

Same as r.m.s. voltage

Threshold value

Percentage of the nominal voltage value

Meas. system

Complied with IEC61000-4-3
*r.m.s. values are calculated from one waveform with half-wave overlapping.
Swell, dip detection for multi-phase system:

Starts when any one of events starts at any ch, Ends when it terminates.

INT detection for multi-phase system:

Starts when the event starts at all chs, Ends when it terminates at any one of
the chs.

Accuracy

10% - 150% (to 100V or higher nominal voltages)

: nominal voltage ±1.0%

Out of above range

: ±0.4%rdg±0.4%f.s.

Errors of event duration measurement at 40 - 70Hz

: within 1-cycle

Detection channel (ch)
1P2W-1 to 4

V

1

1P3W-1 to 2

V

1 ,

V

2

3P3W-1 to 2

Line voltage V

12 ,

V

32

3P3W3A

Line voltage V

12 ,

V

23 ,

V

31

3P4W

V

1 ,

V

2 ,

V

3



Advertising