10.4 Specification of Clamp sensor

KEW6315

- 155 -

KEW6315

<MODEL8141 >

<MODEL8142 >

<MODEL8143 >

Rated current

AC1000mArms

Output voltage

AC0 - 100mV(AC100mV/AC1000mA)

Measuring range

AC0 - 1000mArms

Accuracy

(sine wave input)

±1.0%rdg±0.1mV (50/60Hz)

±2.0%rdg±0.1mV (40Hz - 1kHz)

Phase

characteristics

-------------

Temp. & humidity

range (guaranteed

accuracy)

23±5ºC, relative humidity 85% or less (no condensation)

Operating temp.

range

0 - 50ºC, relative humidity 85% or less (no condensation)

Storage temp.

range

-20 to 60ºC, relative humidity 85% or less (no condensation)

Allowable input

AC100Arms (50/60Hz)

AC200Arms (50/60Hz)

AC500Arms (50/60Hz)

Output impedance

Approx. 180Ω

Approx. 200Ω

Approx. 120Ω

Location for use

In-door use, altitude 2000m or less

Applicable

standards

IEC 61010-1,IEC 61010-2-032

Meas. CAT. III (300V), Pollution degree 2

IEC61326 (EMC standard)

Withstand voltage

AC3540V/5 sec

Between Jaws – Enclosure,

Jaws – Output terminal, and
Enclosure – Output terminal

Insulation

resistance

50MΩ or more/ 1000V

Between Jaws – Enclosure,

Jaws – Output terminal, and
Enclosure – Output terminal

Max conductor size

Approx. ø24mm (max)

Approx. ø40mm (max)

Approx. ø68mm (max)

Dimension

100(L)×60(W)×26(D)mm

(protrusions are not included)

128(L)×81(W)×36(D)mm

(protrusions are not included)

186(L)×129(W)×53(D)mm

(protrusions are not included)

Cable length

Approx. 2m

Output terminal

MINI DIN 6PIN

Weight

Approx. 150g

Approx. 240g

Approx. 490g

Accessory

Instruction manual

Carrying case

Optional parts

7146 (Banana ø 4 Adjuster plug)

7185(Extension cable)