Settings for Harmonic analysis

KEW6315

- 63 -

KEW6315

Settings for Harmonic analysis

“THD calculation”

THD stands for ”Total Harmonic Distortion”. Select “THD-F” to calculate the total harmonics distortion

based on the basic wave and “THD-R” to do the calculation based on all rms values.

Selection

THD-F (based on basic wave)/ THD-R (based on all rms values)

* Default setting is highlighted in gray.

Move the blue highlight to “THD calc.”.

Show the pull-down menu.

Select the calculation method.

Confirm.

Cancel.

”MAX hold”

Turn on the MAX hold to show the mark indicates the max rate of content on a harmonics graph.

Selection

ON/ OFF

* Default setting is highlighted in gray.

Move the blue highlight to “MAX hold”.

Show the pull-down menu.

Turn on/ off.

Confirm.

Cancel.