10.4 Specification of Clamp sensor

KEW6315

- 156 -

<KEW8146 >

<KEW8147 >

<KEW8148 >

AC 30Arms (42.4Apeak)

AC 70Arms (99.0Apeak)

AC 100Arms (141.4Apeak)

AC0 - 1500mV(AC50mV/A)

AC0 - 3500mV(AC50mV/A)

AC0 - 5000mV(AC50mV/A)

AC0 - 30Arms

AC0 - 70Arms

AC0 - 100Arms

0 - 15A

±1.0%rdg±0.1mV (50/60Hz)

±2.0%rdg±0.2mV (40Hz - 1kHz)

15 - 30A

±5.0%rdg (50/60Hz)

±10.0%rdg (45 - 1kHz)

0 - 40A

±1.0%rdg±0.1mV (50/60Hz)

±2.0%rdg±0.2mV (40Hz - 1kHz)

40 - 70A

±5.0%rdg (50/60Hz)

±10.0%rdg (45 - 1kHz)

0 - 80A

±1.0%rdg±0.1mV (50/60Hz)

±2.0%rdg±0.2mV (40Hz - 1kHz)

80 - 100A

±5.0%rdg (50/60Hz)

±10.0%rdg (45 - 1kHz)

-------------

23±5ºC, relative humidity 85% or less (no condensation)

0 - 50ºC, relative humidity 85% or less (no condensation)

-20 to 60ºC, relative humidity 85% or less (no condensation)

AC30Arms (50/60Hz)

AC70Arms (50/60Hz)

AC100Arms (50/60Hz)

Approx. 90Ω

Approx. 100Ω

Approx. 60Ω

In-door use, altitude 2000m or less

IEC 61010-1,IEC 61010-2-032

Meas. CAT. III (300V) Pollution degree 2

IEC61326

AC3540V/5 sec

Between Jaws – Enclosure,

Enclosure – Output terminal, and

Jaws – Output terminal

50MΩ or more/ 1000V

Between Jaws – Enclosure, Enclosure – Output terminal, and Jaws – Output terminal

Approx. ø24mm (max)

Approx. ø40mm (max)

Approx. ø68mm (max)

100(L)×60(W)×26(D)mm

128(L)×81(W)×36(D)mm

186(L)×129(W)×53(D)mm

Approx. 2m

MINI DIN 6PIN

Approx. 150g

Approx. 240g

Approx. 510g

Instruction manual

Cable marker

7146 (Banana ø 4 Adjuster plug)

7185(Extension cable)