KYORITSU 6315 Instruction Manual User Manual

Page 156

Advertising
background image

KEW6315

10.4 Specification of Clamp sensor

KEW6315

- 154 -

<KEW8129 >

<KEW8130 >

300A Range:

AC 300 Arms( 424Apeak)

1000A Range:

AC 1000 Arms(1414Apeak)

3000A Range:

AC 3000 Arms(4243Apeak)

AC 1000 Arms(1850Apeak)

300A Range: AC0 - 500mV(AC500mV/AC 300A):1.67mV/A

1000A Range: AC0 - 500mV(AC500mV/AC1000A):0.5mV/A
3000A Range: AC0 - 500mV(AC500mV/AC3000A):0.167mV/A

AC0 - 500mV

(AC500mV/AC1000A):0.5mV/A

300A Range:

30 - 300Arms

1000A Range:

100 - 1000Arms

3000A Range:

300 - 3000Arms

AC0 - 1000Arms

±1.0%rdg (45 - 65Hz)

(at the center point))

±0.5%rdg±0.2mV (45 - 65Hz)

±1.5%rdg±0.4mV (40Hz - 1kHz)

within ±1.0°

(in each measuring range: 45 - 65Hz)

within ±2.0° (45 - 65Hz)

within ±3.0°(40 - 1kHz)

23±5ºC, relative humidity 85% or less (no condensation)

-10 - 50ºC, relative humidity 85% or less (no condensation)

-20 to 60ºC, relative humidity 85% or less (no condensation)

AC3600Arms (50/60Hz)

AC1300Arms (50/60Hz)

Approx. 100Ω or less

In-door use, altitude 2000m or less

IEC 61010-1,IEC 61010-2-032

Meas. CAT. III (600V) Pollution degree 2

IEC61326

IEC 61010-1,IEC 61010-2-032

Meas. CAT. III (600V)/CAT.IV (300V) Pollution degree 2

IEC61326

AC5350V/5 sec

Between circuit – sensor

AC5160V/5 sec

Between circuit – sensor

50MΩ or more/ 1000V

Between circuit – sensor

Approx. ø150mm (max)

Approx. ø110mm (max.)

111(L)×61(W)×43(D)mm (protrusions are not included)

65(L)×25(W)×22(D)mm

Sensor part: Approx. 2m

Output cable: Approx. 1m

Sensor part: Approx. 2.7m

Output cable: Approx.0.2m

MINI DIN 6PIN

8129-1: Approx.410g/8129-2: Approx.680g/8129-3: Approx.950g

Approx.170g

Instruction manual, Output cable(M-7199), Carrying case

Instruction manual, Cable marker, Carrying case

-

Advertising