Ph - setup menu - auto return 4.11 – Metex Shark Multi-Parameter Controllers & Analyzers User Manual

Page 32

Advertising
background image

pH - Setup Menu - Auto Return 4.11

Page 30

S

H

A

R

K

MULTI-PARAMETER CONTROLLER & ANALYZER USER’S MANUAL

pH - Setup Menu - Auto Return 4.11

DOWN

DOWN

DOWN

DOWN

DOWN

Not stored

DOWN

DOWN

Stored

DOWN

DOWN

DOWN

DOWN

UP

DOWN

DOWN

UP

DOWN

DOWN

DOWN

DOWN

DOWN

UP

DOWN

DOWN

UP

CAUTION:

If AUTO RETURN RELAYS is ON, regardless of

the user settings of the states of the relays, Relays

will default to AUTO 10 minutes after the Shark

returns to Run Mode.

UP

NOTE

PRESS THE AND KEYS

TOGETHER TO GO IMMEDIATELY BACK TO

RUN MODE

DOWN

With "N" selected, pressing the
key will NOT store the selection, but
simply return to the AUTO RETURN
Selection Menu. This function is useful if
you wish to view the current selection
without making any changes.

Then press the key to
store the selection and return
to the Auto Return Selection
Menu.

Press the key to
accept the change and move
to the STORE function

Or press the key to highlight

the Y character.

Press the key to accept the change
and move to the RELAYS auto return
function. RELAYS ON will cause the relays to
return to the AUTO mode if the controller
returns to Online after 10 minutes of inactivity.
This ensures the controller will be put back in
control of the process if accidentally left
offline.

Use the or keys
to select either ON or OFF.

Press the key once
which will move the cursor to
the ON or OFF text

Press the key once
which will move the cursor
back to the RH side of the
display.

RUN MODE

To change the MENU
RETURN setting,
Press the key once
which will move the cursor to
the ON or OFF text

Use the or
keys to select either ON or
OFF.

Press the key
once which will move
the cursor back to the
RH side of the display.

MENU ON will cause the controller to exit the menu and
revert back to the online run mode after 10 minutes with no
buttons pressed. This feature ensures that if a user forgets
to return back to run mode, the controller will not be left in
an offline state. If for some reason, the user would like to
remain in the menu mode for extended periods of time, the
AUTO RETURN function can be set to "OFF".

AUTO RETURN is used to select what conditions will
cause the controller to time-out of the operations
menu, or reset the relay override function.

7.15pH 25.0C

SETUP

UTILITIES

CALIBRATION

STORE? Y N

STORE? Y N

AUTO RETURN

RELAYS OFF

>

AUTO RETURN

AUTO RETURN

RELAYS ON >

RELAYS O N >

RELAYS O FF >

AUTO RETURN

AUTO RETURN

AUTO RETURN

AUTO RETURN

AUTO RETURN

MENU ON

>

TEMP SENSOR

TEMP UNIT

PROBE SELECTION

AUTO RETURN

MENU OFF

>

AUTO RETURN

AUTO RETURN

MENU O FF >

MENU O N >

Advertising