Conductivity - utilities menu - relay override 6.5 – Metex Shark Multi-Parameter Controllers & Analyzers User Manual

Page 83

Advertising
background image

Conductivity - Utilities Menu - Relay Override 6.5

Page 81

S

H

A

R

K

MULTI-PARAMETER CONTROLLER & ANALYZER USER’S MANUAL

Conductivity - Utilities Menu - Relay Override 6.5

UP

UP

UP

UP

To Alarm Relay (Relay C) Override

UP

UP

DOWN

DOWN

UP

DOWN

DOWN

DOWN

DOWN

DOWN

DOWN

DOWN

DOWN

DOWN

DOWN

DOWN

DOWN

DOWN

DOWN

DOWN

DOWN

DOWN

DOWN

DOWN

UP

DOWN

DOWN

Relay Override is used to manually override the state of the relays, the user is able to set
the operating mode of the relay as AUTO/ON/OFF (the default and run mode state are
AUTO).
This feature can be used to turn the relays ON or OFF to manually correct the process,
or to shut down an ancillary device to perform maintenance. When in the Relay Override
mode, the outputs are no longer placed on hold as they are when in the other menus.

If you wish to Override Relay B,
Press the key once
which will move the cursor over
to the AUTO/ON/OFF text

If you wish to Override Relay
A, Press the key once
which will move the cursor
over to the AUTO/ON/OFF text

If you do not wish to
Override Relay B, then
use the key to
the Alarm Relay

If you do not wish to
Override Relay A, then
use the key to
move to Relay B

RUN MODE

UP

NOTE

PRESS THE AND KEYS

TOGETHER TO GO IMMEDIATELY BACK TO

RUN MODE

DOWN

If you wish to accept the
Override setting,
Press the key once
to move the cursor to the
RH of the display

Then use the key
to move to the Override
setting for Relay B

CAUTION:

Note that if the Relay Auto Return Menu is set to

"ON", the controller will place all these settings

back to AUTO if the controller is put back in run

mode, and there is no button activity for 10

minutes.

Use the or key to
change the Override state from
AUTO - controlled by process
settings
ON - relay forced on
OFF- relay forced off
The relay will react
immediately.

Use the or key to
change the Override state from
AUTO - controlled by process
settings
ON - relay forced on
OFF- relay forced off
The relay will react
immediately.

If you wish to accept the
Override setting,
Press the key once
to move the cursor to the
RH of the display

To use the Relay Override
function, press the key

Then use the key
to move to the Override
setting for Relay A

RELAY OVERRIDE

RELAY B A UTO >

RELAY OVERRIDE

RELAY B O N >

RELAY OVERRIDE

RELAY B O FF >

RELAY A O FF >

RELAY OVERRIDE

RELAY A O N >

RELAY OVERRIDE

RELAY OVERRIDE

RELAY A A UTO >

RELAY OVERRIDE

MANUAL TEST MODE

RELAY OVERRIDE
RELAY B AUTO

>

1000uS 25.0C

RELAY A AUTO >

RELAY OVERRIDE

CALIBRATION

UTILITIES

RELAY B ON

>

RELAY B AUTO

>

RELAY B OFF

>

RELAY OVERRIDE

RELAY OVERRIDE

RELAY OVERRIDE

RELAY A ON

>

RELAY A AUTO >

RELAY A OFF

>

RELAY OVERRIDE

RELAY OVERRIDE

RELAY OVERRIDE

Advertising