Operator control panel, Numbering, Operator control panel numbering – HP EML E-series Tape Libraries User Manual

Page 22

Advertising
background image

Figure 17 Ports on the switch for the internal network

1. 10/100Base-TX RJ-45 ports

Operator control panel

The OCP displays library status information and enables you to access the library menus with a
touch screen. Use these menus to view and change the library settings, move tape cartridges,
obtain status information, or run diagnostic tests. Functions provided by the OCP are:

Robotic and tape drive firmware revision reporting

Library configuration

Library and tape drive serial number reporting

Critical component status report

Critical component failure notification

Ability to move tapes to and from any location

Ability to configure barcode label length and justification reporting to the front panel and to
the host

Access to error information

Adjust screen contrast

Figure 18 Location of the OCP

Numbering

All of the tape cartridge slots and tape drives in a library are numbered with a coordinate system.
You might see these numbers in your application software or in error or diagnostic messages. Error

22