Figure 52 Screw locations on the base-module power supply

WARNING!

The power supply might be hot.

5.

Pull the handle on the power supply to remove it from the library.

6.

The bracket is not part of the replacement kit. You must move the bracket from the original
power supply to the new power supply. Remove the two 6-32 x 1/4-inch Torx screws that
attach the bracket to the power supply with a T-15 Torx screwdriver.

Figure 53 Removing the base-module power supply bracket

Replacing a power supply in the base module or tape drive expansion module

1.

Attach the bracket to the new power supply with two 6-32 x 1/4-inch Torx screws. Use a T-15
Torx screwdriver.

2.

Slide the power supply into the library.

3.

Attach the power supply to the library with two 6-32 x 3/8-inch Torx screws.

4.

Plug the power cord into the power supply.

5.

If the power to the library was previously turned off, turn on the power to the library.

Power supply in the card cage expansion module