Installation for direct vent indoor models, Venting instructions, General – State 520 User Manual

Page 10

Advertising
background image

Installation 

10

Page

 

 
Improper venting of this appliance can result in excessive levels of carbon monoxide 
which can result in severe personal injury or death.

 

When installing the vent system, all applicable national and local codes must be 
followed. If you install thimbles, fire stops or other protective devices and they 
penetrate any combustible or noncombustible construction, be sure to follow all 
applicable national and local codes.

 

  

INSTALLATION FOR DIRECT VENT INDOOR MODELS

 

The Direct Vent Indoor models are equipped with a thermistor and hi‐limit switch for the exhaust gas, 
detecting excess temperatures within the flue and enabling the unit to safely stop operations if needed.

 

 

These  components  are  always  monitoring  exhaust  gas  conditions  in  order  to  prevent  heat  damage  to 
PVC (Plastic) venting if PVC is used.

 

If  the  exhaust  gas  temperature  exceeds  140°F,  these  components  will  enable  the  unit  to  safely  stop 
operations.    (For  the  Outdoor  model,  these  components  are  not  available  since  there’s  no  exhaust 
venting required.)

 

 

 The Direct Vent Indoor model requires a 

4”  make‐up  intake  air  supply  pipe.  The 
intake pipe must be sealed airtight. 

 Air supply pipe can be made of ABS, PVC, 

galvanized  steel,  corrugated  stainless 
steel, or Category lll / IV stainless steel. 

 Sidewall venting is recommended for the 

Direct  Vent  Indoor  model.  Vertical 
venting (roof termination) is acceptable. 

 The 

manufacturer 

recommends 

running  the  exhaust  vent  and  the 
intake pipe as parallel as possible. 

 The PVC adaptor is used to make the 

connection  between  the  Direct  Vent 
Indoor  model  vent  collar  and  PVC 
vent pipe easier and for maintenance 
purposes.

 
 
 
 
 
 

VENTING INSTRUCTIONS 

‐General‐

 










The Direct Vent Indoor models must be vented in accordance with the section “Venting of Equipment" 
of the  latest edition of the National Fuel  Gas  Code: ANSI  Z223.1/NFPA 54 in the United  States  and/or 
Section  7  of  the  CAN/CSA  B149.1  Natural  Gas  and  Propane  Installation  Code  in  Canada,  as  well  as 
applicable local building codes.

 

The use of venting materials approved for Category III/IV appliances is recommended whenever possible. 
However, the Direct Vent Indoor models may also be vented with plastic pipe materials such as PVC. For 
details, please refer to the Exhaust Vent (PVC Vent) section on p. 11. Vent installations in Canada which 
utilize plastic vent systems must use venting that complies with ULC S636.

 

WARNING 

Top 12” 

Side 3” 

Back 0.5”

Side 3” 

Front 4” 

(24” Recommended 
for Maintenance) 

Bottom 12” 

Keep the clearances.