Error codes, Single unit installations, Easy‐link system for the 520 (t‐h2) models only – State 520 User Manual

Page 42: Troubleshooting

Advertising
background image

 Troubleshooting 

42

Page

 

ERROR CODES

 

 

The units are self diagnostic for safety and convenience when trouble shooting. 

If there is a problem with the installation or the unit, it will display a numerical error code on the 3‐

digit  7‐Seg.  LED  on  the  computer  board  (visible  through  a  window  on  the  front  cover)  or  remote 
controller (if installed) to communicate the source of the problem. 

Consult the table on the following page for the cause of each error code.   

 













 

‐Single unit installations‐ 

The 7‐Seg LED and remote controller displays the whole 3‐digit error code. 

 

Example: If your unit has the “321” error code (inlet thermistor failure) 

Water heater: It will display “321” on the 7‐Seg LED. 

Remote controller: It will display “321” on its screen. 

 

‐Easy‐Link system for the 520 (T‐H2) models only‐ 

The 7‐Seg LED of the individual unit with the error in question displays the whole 3‐digit error code.  
The

 

remote controller (if installed) displays a 3‐digit number which signifies which unit has the error, 

and what the error code is.   

 

Example: If Unit #2 has the “321” error code (inlet thermistor failure) 

Water heater #2: It will display “321” on the 7‐Seg LED, just like in the Single Unit example. 

Remote controller: It will display “232” on its screen.  The first “2” indicates that Unit #2 has the 
error.  The “32” indicates the first two digits of the “321” error code.   


Error code on the 
remote controller 

Error code on the computer board

3‐digit 7‐Seg. LED 

Unit #1 

PARENT 

unit 

Unit #2

CHILD unit 

Unit #3

CHILD unit 

Unit #4

CHILD unit 

Remote controller