Installation 

13

Page

 

1. Connect the PVC adaptor* directly on the exhaust vent collar of the water heater. 
2. Connect a 4” PVC coupler (or 4x3” PVC reducer) to the PVC adaptor. 
3. From the coupler (or reducer), continue on the rest of the vent run with 4” PVC pipe (or 3” PVC 

pipe.) 

(For Exhaust) 

 























Horizontal Installation Diagram 

(With elbow terminations) 

Horizontal Installation Diagram  
(With 3” PVC Concentric Termination) 

Keep a 1” clearance between wall 
and the intake section of the 
concentric termination.  See the 

diagram to the left. 

‐PVC Venting Illustrations‐

How to install PVC venting with the

 Direct Vent Indoor models

  

Connection between exhaust vent collar and PVC piping
See the next page for instructions. 

Wall

Connection between exhaust vent collar and PVC piping
See the next page for instructions. 

Wall

1” minimum 
clearance 

Concentric Termination

Insert the bird screen included with 
the termination 

Vertical Installation Diagram 

Roof

Roof Flashing

Fire stop