 Normal Operation 

37

Page

 

DO NOT set to 185  °F if  you use your water heater in a  recirculation system. This 
will cause damage to the heater and void the warranty.
 

(unit:°F)

 
 

 












 The temperature has been preset at the factory to 120°F (49°C).  
 If temperatures other than the ones listed above are required, the remote controller can provide a 

couple more temperature options.  Refer to p. 7 for a list of available temperatures on the remote 
controller.  

 When the flow sensor detects flow higher than 0.5 GPM, a single LED tick mark on the left side of the 

3‐digit 7‐Seg. LED will blink to indicate that the unit is working. 

 

<How to set the hot water temperature of the water heater>  

1. Take off the water heater’s front cover. 
2. Press the either “Increase” button or the “Decrease” button on the computer board to increase 

or decrease the set temperature.  The 3‐digit 7‐Seg. LED will display the available set 
temperatures.   (Figure.1) 

3. Scroll to the desired set temperature.  

   

 
 

 

 

 


 

100  105  110  115  120  125  135

140

145

150

155

160

165  170  175  185

Set temperature (Example 110°F)

Temperatures available

Computer board

Figure.1 

Example: tick mark next to the 110°F set temperature display

Decrease button 

3‐digit 7‐Seg LED 

Increase button