‐Dual‐purpose hot water heating‐ 

(Domestic and Space Heating): 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* The circulation pump is to provide no less than 2 GPM and no more than 4 GPM through each activated
water heater unit in the system.
 

Priority Control Devices such as a flow switch, an Aquastat or other electronic 

controller can be used to prioritize the domestic water system over the heating 
system. 

 Follow all local codes, or in the absence of local codes, follow the most recent 

edition of the National Standard Code, ANSI Z21.10.3. 

 This illustration is a concept design only.  The reference to the 1/8

th

 hole in check 

is only for the State of Massachusetts. There are a wide variety of variations to 
the application of controls and equipment presented. Designers must add all 
necessary safety and auxiliary equipment to conform to code requirements and 
design practice. For more details, contact the manufacturer. 

 

WARNING 

Takagi

P

T

An approved Pressure Only

Relief Valve, Tie to Location

approved by Local Codes and
Must Meet BTU Rating of Takagi
Model Used

Unions

4" Gas Exhaust Vent (Discharge

Must Comply with Local and
State Codes). Can Not Be
Common Vented with Other

Appliances

Atmospheric
Vacuum Breaker

Pump (Must Be Sized Properly

With Each Application). Pump
Shall Run 60 Seconds Every 6

Hours

Pressure

Gauge

Apply Correct
Thermal

Expansion

Tank-Size Per
Application

Tempered
Water To

House

Cold Inlet

Shut-Off
Valve

Check Valve Will
Have 1/8" Hole in
Check, As Per
Mass. Code

Thermometer

Thermostatic Mixing Valve

Shut-Off
Valves

Check Valve

Hot

Water
Outlet

Cold
Water
Inlet

T-Handle Gas
Shut-Off Valve

**Maximum allowable distance of
50-Ft. from water heater and
heating panel

Heating Coil

(used with air-handler)

Diagramatic Layout of Radiant Heating and

Domestic Water Heater Per Mass. Code

Thermometer

Check

Valves

Gas
Inlet

Drain
Plug

Water

Filter

120 VAC Switch or Outlet

An approved Pressure Only Relied 
Valve, Tie to Location approved By 
Local Codes and Must Meet BTU 
Rating of water heater Model Used

 