 Troubleshooting 

41

Page

 

PROBLEM 

SOLUTIONS 

‐ 

WAT

ER

 HEATER

 ‐

 

Unit does not ignite when 
water goes through the 
unit.

 

 

 Is the flow rate over 0.5 GPM? (p. 36) 
 Check for the filter on cold water inlet. (p. 39) 
 Check for reverse connection and cross connection. 
 If you use the remote controller, is the power button 

turned on?  

The fan motor is still 
spinning after operation 
has stopped.

 

 

 This is normal. After operation has stopped, the fan motor 

keeps running for 35 seconds in order to re‐ignite quickly, 
as well as purge all the exhaust gas out of the flue.   

Unit sounds abnormal 
while in operation

 

 Contact the manufacturer at 1‐877‐737‐2840

‐Re

m

o

te

 control

ler:

  

9007606005

 (TM

‐RE3

0

(OPTIONAL)

 

Remote controller does not 
display anything when the 
power button is turned on.

Press the ON/OFF button on the remote. 

If the LED lights up ⇒
 This is normal.  When the unit has not operated for five 

minutes or more, the display turns off to converse energy. 

If the LED does not light ⇒
 Make sure the unit has power supply. 
Make sure the connection to the unit is correct.(p. 23)  

An ERROR code is 
displayed.

 

 Please see p. 42. 

‐EASY

‐LINK

 SYSTEM

 

How are the unit numbers 
assigned? 

 For an Easy‐Link system, the Parent unit is always labeled 

#1 and all other subsequence Child units are numbered 
randomly. 

 To check which numbers are assigned to which Child units, 

push the button on the computer board of any Child unit 
as shown below.  The unit number will be displayed on the 
3‐digit 7‐Seg. LED. 

Button to check 
unit numbers 

3‐digit 7‐Seg. LED 