High‐altitude installations, Installation for outdoor models, Installation – State 520 User Manual

Page 9

Advertising
background image

Installation 

9

Page

 

The dark squares indicate the direction the 
dipswitches should be set to. 

Left bank of dipswitches 

Left bank of dipswitches 

There  is  a  3”  clearance  from 
the  left  and  right  sides  of  the 
unit  to  combustible  and  non‐
combustible 
surfaces.   However,  if  any 
portion  or  area  of  the  surface 
is  exposed  to  the  exhaust 
fumes (i.e. directly to the sides 
of  the  vent  cap),  that  surface 
must be at least 24” away.   

Keep the clearances. 

2,500 to 4,000 ft  4,000 to 5,000 ft

Altitude 

HIGH‐ALTITUDE INSTALLATIONS

 

Check the elevation where your water heater is installed.  Set dipswitches shown in the table below 
depending on the altitude. These dipswitches (No. 5 and No. 6) are on the computer board on the left 
bank only.

 

 

 

 

0 to 2,500 ft 

(DEFAULT) 

 

 

Over 5,000 ft 

Switch No.5 

OFF 

ON 

OFF 

Consult  
our  Technical 
Services 
Department  

 at 1‐877‐ 

737‐2840 

Switch No.6 

OFF 

OFF 

ON 


 

INSTALLATION FOR OUTDOOR MODELS 

1. Install the Outdoor model only in areas with mild, temperate climates. 

2. The Outdoor model shall be wall‐mounted or mounted on a stand. Locate the Outdoor model in 

an open, unroofed area and maintain the following minimum clearances: 

 

 
 

 

 

 

 

   

   

DO NOT adjust any dipswitches on the right bank.

1
2
3
4
5
6
7
8

N O

9

1

0

N O

1
2
3
4
5
6
7
8
9

1

0

N O

1
2
3
4
5
6
7
8
9

1

0

Side 3”

Top 36” 

Side 3” 

Front 24”

Bottom 12”

Back 0.5”