Fault analysis of error codes – State 520 User Manual

Page 43

Advertising
background image

 Troubleshooting 

43

Page

 

FAULT ANALYSIS OF ERROR CODES‐ 

If there is a problem with the installation of the water heater, it will display a numerical error 
code on the 

3‐digit 7‐Seg. LED

 of the computer board or the remote controller (if installed) to 

communicate the source of the problem. 
 

Error 
Code 

Malfunction description 

Diagnosis 

031 

Incorrect dipswitch settings 

Check  the  dipswitch 
settings on PCB 

101 

Warning for the “991” error code 

Call 

the

manufacturer’s  
Technical Dept.  

at 1‐877‐737‐2840

111 

Ignition failure 

Check gas supply 

121 

Loss of flame 

311 

Output thermistor failure

Call 

the 

manufacturer’s 
Technical Dept. 
 at 1‐877‐737‐2840 

321 

Inlet thermistor failure 

331 

Mixing thermistor failure

341 

Exhaust thermistor failure (Direct Vent Indoor models 
only) 

391 

Air‐fuel Ratio Rod Failure

441 

Flow Sensor Failure (Only Easy‐Link system)

510 

Abnormal Main Gas Valve

551 

Abnormal Gas Solenoid Valve

611 

Fan Motor Fault 

621 

Exhaust  fan  motor  Fault  (Direct  Vent  Indoor  models 
only) 

631 

Abnormal External Pump

651 

Water Control Valve Fault (Flow Adjustment function)
(Only Easy‐Link system)

661 

Water Control Valve Fault (Bypass valve function)

701 

Computer board Fault 

711 

Gas Solenoid Valve drive circuit failure

721 

False Flame Detection 

741 

Miscommunication  between  water  heater

and 

remote controller 

761 

Miscommunication  in  Easy‐Link (520  (T‐H2)  models 
only) 

941 

Abnormal  exhaust  temperature (Direct  Vent  Indoor 
models only) 

Lower 

the 

set 

temperature 

991 

Imperfect combustion 

Call 

the

manufacturer’s 
Technical Dept. 
at 1‐877‐737‐2840