D) Normal Control (Default setting): No.5 and No.6 OFF 

 
Feature: 
This mode provides no special pump control. Pump activation can only be turned ON or OFF 
by the remote controller. 
 
Function:
 The pump will run continually all the time as long as there is a power supply to the water 
heater. The pump will only stop when the remote is turned off. Water in the loop will be maintained 
at the set temperature of the water heater.  
 
 

 

 

Switch No.5 

ON 

OFF

ON

OFF 

Switch No.6 

OFF 

ON

ON

OFF 









The dark squares indicate the direction the dipswitch should be set to. 