Initial operation, For your safety, read before operating – State 520 User Manual

Page 33

Advertising
background image

Initial Operation 

33

Page

 

 
 
 

Check the GAS and WATER CONNECTIONS for leaks before firing unit for the first time. 
 Open the main gas supply valve to the unit using only your hand to avoid any spark.  Never use 

tools. If the knob will not turn by hand, do not try to force it; call a qualified service technician. 
Forced repair may result in a fire or explosion due to gas leaks.   

 Be sure to check for the presence of leaking gas toward the bottom of the unit because some 

gases are heavier than air and may settle towards the floor. 

Check the GAS PRESSURE. Refer to p. 17.  
 Do not try to light the burner manually. It is equipped with an electronic ignition device which 

automatically lights the burner. 

Check for PROPER VENTING and COMBUSTIBLE AIR to the water heater. 
Purge the GAS and WATER LINES to remove any air pockets.  
 Do not use this water heater if any part has been submersed under water. Immediately call a 

qualified service technician to inspect the water heater and to replace any damaged parts.   

 

INITIAL OPERATION




























1. Once  the  above  checks 

have  been  completed, 

please  clean  filter  of  any 
debris.  Refer  to  p.  39  for 

instructions. 

2. Fully  open  the  manual 

water  control  valve  on  the 

water supply line. 


3. Open  a  hot  water  tap  to 

verify 

that 

water 

is 

flowing to that tap.  

 
 
 
 
 

Then close the hot water tap.

4. Fully open the manual gas 

control valve installed.  


5. Turn  on  the  120  volt  60  Hz 

power  supply  to  the  water 

heater. 

6. Now  you  are  ready  to 

enjoy  hours  of  endless 

hot water. 

FOR YOUR SAFETY, READ BEFORE OPERATING 

IF YOU SMELL GAS:

 

 Do not try to start the water heater. 
 Do not touch any electric switches; do not use any phone in your building. 
 Immediately call your gas supplier from a neighbor’s phone. Follow the gas 

supplier’s instructions. 

 If you cannot reach your gas supplier, call the fire department. 

CAUTION