Pump control mode, Installation – State 520 User Manual

Page 25

Advertising
background image

Installation 

25

Page

 

 

PUMP CONTROL MODE 

The water heater provides the four types of the pump control 
modes.  The pump control modes are selected by changing 
dipswitch settings. The dipswitches that change the pump control 
modes are located in the right bank of dipswitches in the upper‐
left quadrant of the computer board in the water heater. (See 
right.)  These 4 modes only affect pumps that are connected to 
the water heater pump control (p.24) 

 
 

A) Recirculation Control: No. 5 ON 

 

Feature:  Maintaining temperature in a standard recirculation loop, providing hot water in a quicker 
amount of time. 

 
Function:
 The pump is only set to run when the temperature of the water in the recirculation loop is 
more than 9°F below the set temperature of the water heater.  
The pump will run for about 1 minute every 30 minutes to determine whether the water 
temperature in the entire recirculation loop is more than 9°F below the set temperature. 
If the water temperature is more than 9°F below the set temperature, the pump will remain running 
until the water in the loop reaches the set temperature. Otherwise, the pump will stop for another 
30 minutes.  
If the inlet thermistor of water heaters detects that the water temperature is more than 9°F below 
the set temperature before those 30 minutes have elapsed, the pump will activate immediately and 
remain running until the water in the loop reaches the set temperature.

 

 

 

B) Storage Tank Circulation Control: No.6 ON 

 

Feature: This is to ensure a higher rate of recovery for storage tank applications. 
 
Function:  The  water  heater  heats  the  water  5.4°F  higher  than  its  set  temperature.  The  circulation 
pump  between  the  storage  tank  and  the  water  heater  will  continually  remain  running.  After  set 
temperature has been reached in the storage tank, the water heater will fire off and limit the water 
flow rate to less than 2.6 GPM, to continually monitor the temperature throughout the system. 
 
Note: In this mode, the pump will continually remain running.

 

 
 

C) Energy Conserving Recirculation: No.5 and No.6 ON 

 

Feature: Operates similarly to the standard Recirculation Control mode, but saves more energy by 
limiting the temperature within the recirculation loop. 
 
Function: The temperature of the recirculation loop is never kept above 120°F (49 °C), regardless of 
the set temperature of the water heater. 
 
 
 
 