Vent termination, Installation – State 520 User Manual

Page 12

Advertising
background image

Installation 

12

Page

 

 

Improper installation can cause nausea or asphyxiation, severe injury or death from 
carbon monoxide and flue gases poisoning. Improper installation will void product 
warranty.

 

Do not common vent this appliance with any other vented appliance (Do not terminate vent 

into a chimney.  If the vent must go through the chimney, the vent must run all the way through 
the chimney with Category III / IV approved or Special BH vent pipe). 

 The  maximum  length  of  exhaust  vent  piping  must  not  exceed  50  ft.  (deducting  5  ft.  for  each 

elbow used in the venting system).  Do not use more than 5 elbows. 

 When the horizontal vent run exceeds 5 ft., support the vent run at 3 ft. intervals with overhead 

hangars. 

 

Diameter 

Max. No. of Elbow 

Max. Vertical and Horizontal (Total) Vent Length

4” 

50 ft. 

 

         *For each elbow added, deduct 5 ft. from max. Vent length. 

No. of Elbows 

Max. Vertical or Horizontal Length 

50 ft. 

45 ft. 

40 ft. 

25 ft. 

 
 

‐Vent termination ‐ 

 




 The vent terminator provides a means of installing vent pipe through the building wall and must be 

located  in  accordance  with  ANSI  Z223.1/NFPA  54,  or  in  Canada  with  CAN/CSA‐B149.1  and  local 
applicable codes. 

 A proper sidewall direct‐vent terminator is recommended when the water heater is vented through a 

sidewall.    

 

General rules for venting the Direct Vent Indoor models are: 
1.

Place the water heater as close as possible to the vent terminator. 

2.

The vent collar of the water heater must be fastened directly to an unobstructed vent pipe or PVC 
adaptor. 

3.

Do not weld the vent pipe to the water heater collar.  

4.

Do not cut the vent collar of the unit. 

5.

The weight of the vent stack must not rest on the water heater.  

6.

The  vent  must  be  easily  removable  from  the  top  of  the  water  heater  for  normal  service  and 
inspection of the unit. 

7.

The water heater vent must not be connected to any other gas appliance or vent stack. 

8.

Avoid locating the water heater vent terminator near any air intake devices. These fans can pick 
up  the  exhaust  flue  products  from  the  water  heater  and  return  them  to  the  building.  This  can 
create a health hazard. 

9.

Avoid using an oversized vent pipe or using extremely long runs of the pipe.

 

10. Locate  the  vent  terminator  so  that  it  cannot  be  blocked  by  any  debris,  at  any  time.  Most  codes 

require that the terminator be at least 12 inches above grade, but the installer may determine if it 
should be higher depending on the job site condition and applicable codes. 

11. For rooftop venting, a rain cap or other form of termination that prevents rain water from entering 

into the water heater must be installed. 