View error table – Vaisala HMW90 User Manual

Page 79

Advertising
background image

Chapter 6 ____________________________________________________________ Troubleshooting

VAISALA ________________________________________________________________________ 77

View Error Table

Use the ERRT command to view the table of possible transmitter errors.

The table includes error ID, error count since last reset, level, current

state, and error text. Most of the errors can be seen also on the display

(see Table 12 on page 76) but there are some that can only be viewed on

the serial line.

ERRT<cr>

Example:

>errt

Id: N: Level:State: Error text

1: 0: CRITICAL:OFF: FLASH memory corrupted

2: 0: CRITICAL:OFF: Parameter read (using defaults)

3: 0: CRITICAL:OFF: Parameter write

4: 0: CRITICAL:OFF: HTM10 03 FLASH Corrupted

21: 0: ERROR:OFF: HTM10 04 RH measurement

22: 0: ERROR:OFF: HTM10 05 T measurement

23: 0: ERROR:OFF: HTM10 01 Continuous communication failure

41: 0: WARNING:OFF: HTM10 02 Single Communication failure

42: 0: WARNING:OFF: HTM10 06 Device Descriptor match

43: 0: WARNING:OFF: Factory parameter memory not consistent

Table 13

Error Messages on the Serial Line

Error ID Possible Cause and Solution

23

41

Communication failure with HTM10

module. Reconnect the module and check that it sits firmly in place.

4

21

22

Problem with the HTM10 module.

1. Check for damage or missing humidity sensor. Note that the

humidity sensor is not included on TMW-type transmitters since

they only measure temperature.

2. Replace the module if unable to remove the problem.

1

2

3

42

43

Internal problem with the transmitter.

1. Reset the transmitter.

2. Restore the factory settings using service port or DIP switches

if reset does not help.

Advertising