Chapter 6. Diagnostics

6-2

MX2800 STS-1 User Manual

61200659L1-1

VT/PORT LOOPBACKS

After you select the number that corresponds with the line you want
to test, the menu in Figure 6-2 appears. The number selected
(1-28) refers to the VT number. The Port (T1/E1) that will be tested
is the port mapped to the selected VT number. The sections
following the figure provide descriptions and illustrations of the
testing options. Select

1-D

ATA

M

ODE

to end a test in progress.

Figure 6-2. VT/Port Diagnostics Menu

Tributary

A

T

RIBUTARY

loopback loops the selected VT/Port back to the

network (STS-1). The T1/E1 is looped back through the STS-1
mapper. During this loopback, the corresponding DSX-1/E1 input
is overwritten by the outgoing DSX-1/E1 signal. See Figure 6-3 on
page 6-3
for an illustration of this test.