Power supply alarms -24 – ADTRAN 4200659L1 User Manual

Page 70

Advertising
background image

Chapter 3. Configuration

3-24

MX2800 STS-1 User Manual

61200659L1-1

Power Supply Alarms

Alarm

Description

Activity Loss
Status

When enabled, the CRITICAL relay will be
thrown if the Activity Loss Status indicates the
failure of an internal clock. The alarm will remain
active until the condition clears or the alarm is
acknowledged by the user.

Alarm

Description

Malfunction

Power supply card is no longer working. The
unit has switched to the backup power supply or
battery backup.

Power Low

Power supply’s output level is abnormally low.

Power Fail

Power supply card’s input power is lost.

Bat. Backup
Active

Battery charger has lost its AC source and is
now running off the battery backup.

Battery Low

Battery backup has reached a critical energy
point at which it may be unable to supply the unit
with sufficient power to maintain operation.

Temperature
High

Power supply card temperature is above
normal.

Temperature
Critical

Power supply card temperature is so high that it
may suffer damage.