Timing status, Timing status -8, Clock status -8 current source -8 – ADTRAN 4200659L1 User Manual

Page 98: Clock status, Current source

Advertising
background image

Chapter 4. Status

4-8

MX2800 STS-1 User Manual

61200659L1-1

TIMING STATUS

The following entries describe the state of the transmit timing
subsystem, including the status of the selected reference clock(s),
availability and status of the external clock sources, timing
acquisition status, and internal clock failures.

Clock Status

This entry describes the condition of the clock synchronization
circuitry. The clock status can be any of the following values:

N

ORMAL

– clock synchronization is operating normally.

R

ECOVERING

– clock synchronization is in the process of

recovering from a fault.

L

OSS

OF

S

OURCE

– the reference clock source has become

invalid

O

UT

OF

R

ANGE

– the clock synchronization circuit is unable to

track the reference source.

O

UT

OF

L

OCK

– the clock synchronization circuit is unable to

lock to the reference source.

Current Source

Indicates the source of the clock. The values for the clock source
are:

L

OOP

indicates that timing is currently being derived from the

STS-1 receive signal.

PRI E

XT

– indicates that timing is currently being derived from

the source assigned to the primary external clock source.

SEC E

XT

– indicates that timing is currently being derived from

the source assigned to the secondary external clock source.

F

REE

-

RUN

– indicates that transmit timing is currently being

derived from an internal +/-20 ppm (Stratum 4) SONET
minimum clock source.

Advertising