Protection -7, Line coding violations (lcv), Protection – ADTRAN 4200659L1 User Manual

Page 97: Card comm

Advertising
background image

Chapter 4. Status

61200659L1-1

MX2800 STS-1 User Manual

4-7

Protection

This field lists the type of protection mode currently active.
Possible states are listed in the following chart:

Card Comm

This field displays the current state of the communication link
between the two controller cards.

OK

indicates that the cards are

communicating;

F

AILURE

indicates that the cards are not able to

communicate with each other. If there is only one card installed,

N

ON

-R

EDUNDANT

is displayed.

Condition

Description

Network

Both controller cards are installed and everything is
functioning properly. The unit is in full Network
Protection Mode.

Circuit

Unit is in Circuit Protection Mode and everything is
functioning properly,
or
unit is in Network Protection Mode and a failure on
the network has occurred.

None

One controller card is installed,
or
the unit is in Circuit Protection Mode and the
secondary card has failed.

For more information on the different types of Protection Modes, see
Chapter 7, Circuit and Network Redundancy.

Advertising