Circuit and network failure recovery mode, Circuit and network failure recovery mode -4, Table 7-1 – ADTRAN 4200659L1 User Manual

Page 138: Configuration requirements for circuit recovery -4

Advertising
background image

Chapter 7. Circuit and Network Redundancy

7-4

MX2800 STS-1 User Manual

61200659L1-1

Table 7-1. Configuration Requirements for Circuit Recovery

CIRCUIT AND NETWORK FAILURE RECOVERY MODE

In this mode, two controller cards are installed and connected to
two individual STS-1 lines. This is, of course, the most complete
mode of redundancy. In this mode, the primary controller card is
connected to the primary STS-1 line and the secondary controller
card is connected to the secondary STS-1 line. The primary card
and line actively transmit data, while the other card and line stand
by ready to take over if the first card and line fail. For example, if

C

ARD

A

fails, then control switches to

C

ARD

B

and

NET B

.

An important feature of the MX2800 STS-1 is its ability to
internally re-route the network connection if a controller card and
the opposite network connection fail. For example, in the
illustration given in Figure 7-3, failed

NET A

is connected to

healthy

C

ARD

A

; and healthy

NET B

is connected to failed

C

ARD

B

.

Selection Path

Recommended Setting

Config > Network Interface > XCV Threshold

1E-3 (see the following note)

Config > Network Interface > Network Protection

Disabled

Config > Network Interface > Max. Switch Threshold

3

Config > Network Interface > Min. Switching Period

10 seconds

Config > T1/E1 Interface > T1/E1 Circuit Protection

Enable all or select the
T1/E1s that redundant
switching should occur on.

Config > T1/E1 Interface > XCV Threshold

1E-3 (see the following note)

The XCV Threshold settings are based on the error rates
considered acceptable on the STS-1 or DS-1 before switching.