Chapter 4. Status

61200659L1-1

MX2800 STS-1 User Manual

4-9

H

OLDOVER

– indicates that a failure in the selected clock sourc

has occurred and the unit has entered hold-over mode. In this
mode, the last known good clock reference frequency will be
held within 4.1 ppm for a minimum of 24 hours.

PRI Ext. Clock

The PRI EXT Clock alarms indicate when a failure condition is
encountered on the PRImary clock source (if configured). The
possible values for this alarm are:

D

ISABLED

indicates that the selected clock has been disabled

by the user and will not be used.

N

ORMAL

indicates that the clock source is currently being

used a the timing reference.

A

VAILABLE

indicates that the clock source is available to be

used as a timing source if a failure of the current source occurs.

LOS/AIS

indicates that the clock source is not valid due to an

LOS or AIS condition.

F

AIL

indicates that an internal hardware failure on the unit

prevents the clock source from being used.

U

NAVAILABLE

– indicates that the user has specified a T1/E1

port to be used as an external clock source, but the port has not
been enabled.

SEC Ext. Clock

The SEC EXT Clock alarms indicate when a failure condition is
encountered on the SECondary clock source (if configured). The
possible values for this alarm are:

D

ISABLED

indicates that the selected clock has been disabled

by the user and will not be used.

N

ORMAL

indicates that the clock source is currently being

used a the timing reference.

A

VAILABLE

indicates that the clock source is available to be

used as a timing source if a failure of the current source occurs.