Power supply state, System state, Power supply state -5 system state -5 – ADTRAN 4200659L1 User Manual

Page 95: Alarm -5, Alarm

Advertising
background image

Chapter 4. Status

61200659L1-1

MX2800 STS-1 User Manual

4-5

POWER SUPPLY STATE

This field indicates which types of power supplies are installed (AC
or DC) in Card A and Card B and gives their current state.

SYSTEM STATE

The system state fields display information regarding the two
controller cards. The following sections describe these fields in
detail.

Alarm

This field displays what type (if any) of system alarm is currently
recognized by the unit. The condition is displayed until it clears up,

Condition

Description

Normal

The power supply is fully operational.

Error

The controller card cannot communicate with the
power supply.

Power Low

The power supply output level is abnormally low.

Power Fail

The power supply input power is lost.

Charger Fail

The battery backup charger has failed or has lost
its AC connection.

Battery Low

The battery backup has reached a critical energy
point at which it may be unable to supply the unit
with sufficient power to maintain operation.

Temp High

The power supply card temperature is abnormally
high.

Temp Critical

The power supply card temperature is so high that
it will soon shut off completely.

Advertising