ADTRAN 4200659L1 User Manual

Page 78

Advertising
background image

Chapter 3. Configuration

3-32

MX2800 STS-1 User Manual

61200659L1-1

System Timing

Clock Status

there is a change in clock status. The clock
status can be any of the following values:

N

ORMAL

– clock synchronization is

operating normally.
R

ECOVERING

– clock synchronization is in

the process of recovering from a fault.
L

OSS

OF

S

OURCE

– the reference clock

source has become invalid
O

UT

OF

R

ANGE

– the clock synchronization

circuit is unable to track the reference
source.
O

UT

OF

L

OCK

– the clock synchronization

circuit is unable to lock to the reference
source.

Clock Source
Change

there is a Clock Source Change event
indicating that the unit has switched clock
sources. The values for the clock source
change alarm are:

Loop
PRI Ext
SEC Ext
Free-run
Holdover

PRI EXT Clock
Status

a failure condition is encountered on either the
PRImary or SECondary clock sources (if
configured). The possible values for this alarm
are:

D

ISABLED

N

ORMAL

A

VAILABLE

LOS/AIS
F

AIL

U

NAVAILABLE

Trap

If enabled, the unit issues a trap when...

Advertising
This manual is related to the following products: