Chapter 2. Installation and Operation

61200659L1-1

MX2800 User Manual

2-9

rackmount units. Once a modular connector is wired, push it firmly
into the rear panel

NONCRITICAL

or

CRITICAL

connector.

The alarm functions can be enabled or disabled through the

A

LARM

R

ELAYS

section of the

C

ONFIGURATION

menu (see the section Alarm

Relays on page 3-18).

Network Interfaces

The network interfaces are full-duplex circuits provided by four
BNC coaxial cable connections (two for each controller card). The
receive data from the network is connected to the RX (

IN

)

connectors, while the transmit data from the MX2800 STS-1 is
connected to the TX (

OUT

) connectors.

DSX-1/E1 Interfaces

The DSX-1/E1 interfaces are 64-pin Amp connectors. These
interfaces provide Tx and Rx connections between the unit and
equipment such as wire-wrap patch panels, punch-down panels, or
breakout panels.

Power Connection

The DC and AC power connections are described earlier in this
chapter on page 2-2.

Network interfaces must be connected using coaxial cables that have
the shields grounded at both ends.

Connect the DSX-1/E1 interfaces to intra-building wiring only.