Network interface, Network interface -3, Sts-1 configuration -3 – ADTRAN 4200659L1 User Manual

Page 49: Line length -3 timing -3, Figure 3-3, Network configuration menu -3, Sts-1 configuration

Advertising
background image

Chapter 3. Configuration

61200659L1-1

MX2800 STS-1 User Manual

3-3

NETWORK INTERFACE

Select

N

ETWORK

I

NTERFACE

to access the network configuration

parameters (see Figure 3-3). Configure the MX2800 STS-1
network settings to match the STS-1 signal received from the
service provider.

Figure 3-3. Network Configuration Menu

STS-1 Configuration

Use the

STS-1 C

ONFIGURATION

selections described below to

configure the STS-1 network settings to match your application.

Line Length

Set the line length to reflect the physical length of the STS-1
network line. Set to

L

ONG

if the cabling distance is between

225-450 feet; set to

S

HORT

if the distance is less than 225 feet.

Timing

Selects the source of timing used to derive the transmit signal. The
MX2800 STS-1 has three modes of timing operation:

L

OOP

,

F

REE

-

R

UN

, and

E

XTERNAL

.

L

OOP

timing configures the unit to recover

clocking from the STS-1 receive signal. Loss of the STS-1 receive

Advertising
This manual is related to the following products: