Power supply recovery mode, Power supply recovery mode -3, Figure 8-2 – ADTRAN 4200659L1 User Manual

Page 143: Power supply failure recovery mode -3

Advertising
background image

Chapter 8. Power Loss Recovery

61200659L1-1

MX2800 STS-1 User Manual

8-3

POWER SUPPLY RECOVERY MODE

In Power Supply Recovery Mode, two power supply cards are
installed and connected to a single power source (see Figure 8-2).
In this mode, the MX2800 STS-1 can continue to operate during a
power supply failure, without interrupting service. The power
supplies are load sharing, so either power supply can provide power
for the entire unit.

Figure 8-2. Power Supply Failure Recovery Mode

When the unit is configured with dual internal AC power supplies,
this is the only power protection mode available.

MX2800 STS-1

Advertising