Real Time Clock (RTC)

AMD SB600 Register Reference Manual

Proprietary

Page 291

Register Name

Offset Address

Register A

0Ah

Register B

0Bh

Register C

0Ch

Register D

0Dh

AltCentury (when DV0=0)

32h

Century (when DV0=1)

48h

Extended RAM Address Port

50h

Extended RAM Data Port

53h

RTC Time Clear

7Eh

RTC RAM Enable

7Fh

Registers that are implemented in the internal RTC are described below.

Seconds - RW – 8 bits - [RTC_Reg: 00h]

Field Name

Bits

Default

Description

Seconds

7:0

00h

Binary-Code-Decimal format. Range:00 – 59
This register can be set by software (SET bit of Register B = 1)
or can be automatically updated by hardware every second.
When set by software, hardware updating is disabled.

Seconds register

Seconds Alarm - RW – 8 bits - [RTC_Reg: 01h]

Field Name

Bits

Default

Description

Seconds Alarm

7:0

00h

Binary-Code-Decimal format.
If SET bit = 1, Seconds Alarm Register will never match with
Seconds Register, else
If bits [7:6] = [11], Seconds Alarm Register always matches
with Seconds Register.

Seconds Alarm register

Minutes - RW – 8 bits - [RTC_Reg: 02h]

Field Name

Bits

Default

Description

Minutes

7:0

00h

Binary-Code-Decimal format. Range:00 – 59
This register can be set by software (SET bit of Register B = 1)
or can be automatically updated by hardware every minute.
When set by software, hardware updating is disabled.

Minutes register

Minutes Alarm - RW – 8 bits - [RTC_Reg: 03h]

Field Name

Bits

Default

Description

Minutes Alarm

7:0

00h

Binary-Code-Decimal format.
If SET bit = 1, Minutes Alarm Register will never match with
Minutes Register, else
If bits [7:6] = [11], Minutes Alarm Register always matches
with Minutes Register.

Minutes Alarm register

Hours - RW – 8 bits - [RTC_Reg: 04h]

Field Name

Bits

Default

Description

Hours

7:0

00h

Binary-Code-Decimal format. Range:00 – 23
This register can be set by software (SET bit of Register B = 1)
or can be automatically updated by hardware every hour.
When set by software, hardware updating is disabled.