Adjustment relationships, Analog bus adc calibration related adjustments, Synthesizer potentiometer related adjustments – Agilent Technologies E4438C User Manual

Page 97: Am accuracy related adjustments, I/q modulation accuracy related adjustments, Burst modulation accuracy related adjustments, Adjustment relationships -5, Analog bus adc calibration related adjustments -5, Synthesizer potentiometer related adjustments -5, Am accuracy related adjustments -5

Advertising
background image

Adjustments

Adjustment Relationships

4- 5

Adjustment Relationships

Anytime an adjustment is made to the signal generator other related adjustments may be affected. For
optimal performance, whenever an adjustment is performed, the related adjustments should also be
performed.

Analog Bus ADC Calibration Related Adjustments

The following adjustments are optimized if the

“Analog Bus ADC Calibration” on page 4-8

has been run:

“VCO Bias Potentiometer Calibration” on page 4-11

“FM Inverting Amplifier Offset Calibration” on page 4-18

“VBLO Mixer Bias Calibration” on page 4-29

“ALC Modulation Driver Bias Calibration” on page 4-35

“Power Search Calibration” on page 4-39

“I/Q Gain/Offset/Quadrature Calibration” on page 4-41

“I/Q Impairment Calibration” on page 4-42

Synthesizer Potentiometer Related Adjustments

The

Lock Angle Potentiometer Calibration (Not Used with Option UNJ or Option 506)

is preset fully

counter-clockwise in the

VCO Bias Potentiometer Calibration

. Both adjustments should always be performed

together.

“VCO Bias Potentiometer Calibration” on page 4-11

“Lock Angle Potentiometer Calibration (Not Used with Option UNJ or Option 506)” on page 4-12

AM Accuracy Related Adjustments

“Internal Source Calibration” on page 4-10

“AM Audio Path Offset Calibration” on page 4-26

“AM Gain Calibration” on page 4-40

I/Q Modulation Accuracy Related Adjustments

“VBLO Mixer Bias Calibration” on page 4-29

“I/Q Gain/Offset/Quadrature Calibration” on page 4-41

“I/Q Impairment Calibration” on page 4-42

Burst Modulation Accuracy Related Adjustments

“Burst Modulator Calibration” on page 4-27

Advertising