background image

Chapter 3 - Commissioning

BreezeACCESS VL System Manual

70

3.1

Configuring Basic Parameters

3.1.1 Initial Configuration

After completing the installation process, as described in the preceding chapter,
the basic parameters must be configured to ensure that the unit operates
correctly. After the basic parameters have been configured, additional parameters
can be remotely configured via the Ethernet port or the wireless link using Telnet
or SNMP management, or by loading a configuration file.

Refer to section

4.1

for information on how to access the Monitor program using

Telnet and how to use it.

The Basic Configuration menu includes all the parameters necessary for the
initial installation and operation of Subscriber and Access Units. In many
installations, most of these parameters should not be changed from their default
values. The basic parameters and their default values are listed in Table 3-1.

Refer to

Chapter 4

for detailed information on the applicable parameters.

Table 3-1: Basic Parameters

Parameter

Default Value

Comment

Ethernet Port Negotiation Mode

(in Unit Control Parameters)

Auto Negotiation

IP Address

10.0.0.1

Subnet Mask

255.0.0.0

Default Gateway Address

0.0.0.0

DHCP Options

Disable

Access to DHCP

AU: From Ethernet Only

SU: From Wireless Only

ESSID ESSID1

Country Code Select

Depends on factory

configuration

Applicable only for 5.4

and 5.8 GHz units. See

3.1.2 below.

Sub-Band Select (AU)

1

Applicable only if more

than one Sub-Band is

available

Frequency (AU)

The lowest frequency in

the selected Sub-Band

Advertising