Operation Verification

Commissioning

83

3.5.2 Indoor Unit Verification

To verify the correct operation of the indoor equipment, examine the LED
indicators located on the top panel of the SU IDU and AU IDU units, or on the
front panel of the BS-AU module.

Table 3-7 provides information for the BS-AU IDU LEDs. Table 3-8 lists the LEDs
of the PS1073 IDU.

Table 3-7: BS-AU LEDs

Name

Description

Functionality

W-LINK

Wireless link activity

„ Green - At least one SU is associated.

„ Blinking Red - No SU is associated.

„ Off - Wireless link is disabled.

ODU CURRENT

CONSUMPTION

Current Consumption of

the Outdoor Unit

„ Red - over current.

„ Blinking Red - open circuit or below

anticipated current consumption.

„ Green - within tolerance.

ODU STATUS

Outdoor Unit Self-test

„ Green - Self test passed and ODU

ready for operation.

„ Blinking Amber - Testing (not ready

for operation)

„ Red - fatal failure.

IDU PWR

Power indication for the

Indoor Unit

„ Green - IDU power is OK.

„ Off - no power is supplied to the IDU.

ALARM Indoor

Unit

Alarm

Indication

„ Red - a fatal failure indication.

„ Off - IDU is functioning properly.