Alvarion BREEZEACCESS SW VERSION 5.1 User Manual

Page 227

Advertising
background image

Menus and Parameters

Operation and Administration

195

The actual value will be the entered value rounded to the nearest multiple of 128
(N*128).

4.2.6.6.2.2 MIR:

Uplink (SU only)

Sets the Maximum Information Rate of the up-link from the SU to the AU. The
MIR value cannot be lower than the corresponding CIR value.

Available values range and default value are shown in Table 4-14.

The actual value will be the entered value rounded to the nearest multiple of 128
(N*128).

4.2.6.6.2.3 CIR:

Downlink (SU only)

Sets the Committed Information Rate of the downlink from the AU to the SU. The
CIR value cannot be higher than the corresponding MIR value.

Available values range and default value are shown in Table 4-15.

The actual value will be the entered value rounded to the nearest multiple of 128
(N*128).

4.2.6.6.2.4 CIR:

Uplink (SU only)

Sets the Committed Information Rate of the uplink from the SU to the AU. The
CIR value cannot be higher than the corresponding MIR value.

Available values range and default value are shown in Table 4-15.

The actual value will be the entered value rounded to the nearest multiple of 128
(N*128).

Table 4-14: MIR Ranges and Defaults

MIR Uplink

MIR Downlink

Unit

Type

Range (Kbps)

Default (Kbps)

Range (Kbps)

Default (Kbps)

SU-3 128-2,048 2,048

128-3,072

3,072

SU-6 128-4,096 4,096

128-6,016

6,016

SU-8 128-13,440 13,440

128-13,440

13,440

SU-54 128-53,888 53,888

128-53,888

53,888

SU-I 128-4,096 4,096

128-6,016

6,016

Advertising