6 verifying data connectivity – Alvarion BREEZEACCESS SW VERSION 5.1 User Manual

Page 118

Advertising
background image

Chapter 3 - Commissioning

BreezeACCESS VL System Manual

86

Table 3-10: SU-I SNR Bar LED Functionality

SNR Bar LEDs

SNR (typical)

LED 1 (red) is On

Signal is too low (SNR < 4 dB)

LED 2 (green) is On

SNR > 4 dB

LEDs 2 to 3 (green) are On

SNR > 8 dB

LEDs 2 to 4 (green) are On

SNR > 13 dB

LEDs 2 to 5 (green) are On

SNR > 19 dB

LEDs 2 to 6 (green) are On

SNR > 26 dB

LEDs 2 to 7 (green) are On

SNR > 31 dB

LEDs 2 to 8 (green) are On

SNR > 38 dB

LEDs 2 to 9 (green) are On

SNR > 44 dB

LEDs 2 to 9 (green) and 10 (orange) are On

Signal is too high (SNR > 50 dB)

3.5.4 Verifying the Ethernet Connection (Modular

Base station)

After connecting the unit to an Ethernet outlet, verify that the Ethernet Integrity
Indicator, which is the yellow LED embedded in the 10/100 BaseT connector, is
on. This indicates that the unit is connected to an Ethernet segment. The
Ethernet Activity Indicator, which is the green embedded LED, should blink
whenever the unit receives or transmits traffic on the 10/100 BaseT port.

3.5.5 Verifying the Indoor-to-Outdoor Connection

(Modular Base Station)

After connecting the unit to an Ethernet outlet, verify that the Ethernet Integrity
Indicator, which is the yellow LED embedded in the RADIO connector, is on. This
indicates that the unit has detected an Ethernet link connection. The Ethernet
Activity Indicator, which is the green embedded LED, should blink whenever the
unit receives or transmits traffic on the RADIO port.

3.5.6 Verifying Data Connectivity

To verify data connectivity, from the end-user’s PC or from a portable PC
connected to the unit, ping the Access Unit, or try to connect to the Internet.

Advertising