Appendix F - Troubleshooting

BreezeACCESS VL System Manual

238

F.1

Ethernet Port Connection Problems

Problem and Indication

Possible Cause

Corrective Action

The Ethernet Integrity Indicator (the yellow
LED embedded in the Ethernet connector)
is off, and/or the Ethernet Activity Indicator
(the green embedded LED) does not blink
when there should be traffic on the Ethernet
port.

Wrong type of Ethernet
cable

If connected directly to PC-use a
crossed cable. Otherwise-use a
straight cable

Faulty Ethernet cable

Replace cable

The unit does not respond to ping.

Wrong IP configuration

Make sure that the PC is on the same
subnet as the unit*.

Wrong Ethernet port
operation mode

Make sure that the speed and duplex
settings in the PC match the
configuration in the unit (the default is
Auto Negotiation)

Wrong Management
VLAN, User Filtering,
Access to
Management..

Make sure all relevant parameters are
configured properly

* If the IP parameters of the unit are unknown, use the Set Factory Defaults utility to restore
the default factory configuration of all parameters (except to Passwords, general FTP
parameters and AU’s Frequency). The IP address of the unit after setting to factory defaults is
10.0.0.1.