K-Config - Assigning the Peripheral Devices to Master and Auxiliary Device Ports

Setting the Digital Input

In this example, an alarm setting causes a short circuit, thus activating a trigger.

To set the trigger:

1.

Define the GPI/O in the Port Manager.

Check Pullup for short circuit detection; the threshold is set automatically (skip step 2):

Do not check Pullup for voltage level detection; the threshold to be set by the user (proceed to step 2):

2.

Click the Threshold button to define the GPI/O Threshold (minimum from 0 and maximum up to 30V)

according to the indication set by the device (other voltages will not activate the trigger).

Figure 113: GPI/O Threshold Window

To learn more about GPI/O Events, go to

Section

8.4

.

7.2.2

Digital Output

The digital output function is defined by the pull-up setup:

Without Pullup: The port will act as a solid state relay (open/close functions)

The GPI/O maximum voltage is 30V DC and the maximum current is 50mA

With Pullup: the port can be used as a TTL positive logic output (open: ~2.4V; closed:~0.2V)

Setting the Digital Output

Define the GPI/O in the Port Manager:

Once defined as Digital Output, the GPI/O port will appear in the Action Editor > Port Switch, and can be used like any

other relay: